Raising a nonconformity is half the job. The other half — reviewing what the auditee does about it and deciding when it can be closed — comes up on every auditor course and in every follow-up audit. This guide follows the ISO 9001 Auditing Practices Group (APG) paper on reviewing and closing nonconformities. It is educational guidance rather than a requirement, and your certification body or internal audit procedure may set its own rules and deadlines. For writing the finding in the first place, see writing audit findings.
1 Three parts of a response
The APG uses the ISO 9000 definitions:
- Nonconformity — non-fulfilment of a requirement
- Correction — action to eliminate a detected nonconformity (replacing a faulty product, swapping an obsolete procedure for the current one)
- Corrective action — action to eliminate the cause of a nonconformity and to prevent recurrence
A full response has a correction, an analysis of the cause, and corrective action. The order can vary. The APG's example: if a car's brake-pad warning light comes on and you replace the pads straight away, you may have wasted time and money if the real fault was the sensor. With software, too, it is unwise to correct before the cause is known.
2 Finding the cause
Corrective action can't be taken without first finding the cause. Methods range from simple brainstorming to fishbone diagrams and "5 whys", and the APG expects auditors to know how these tools should be used. Its version of 5 whys starts with the incident, moves to the immediate factors — people, machine, material, method, measurement, environment — and then asks why again until it reaches a cause in the management system.
The paper also warns against stopping at the first factor found. A sound analysis lists the possible factors, sorts them into "not able to confirm", "possible" and "confirmed", keeps a record of the reasoning, and works on until a root cause is confirmed (or recorded as a possible root cause). Two further questions to ask:
- Was the failure systematic, or genuinely a one-off? Treating a systematic failure as an accident means it will come back.
- Did it happen because something sits outside the management system altogether?
3 Reviewing the response
Before accepting a response, the APG says the auditor should confirm there is documented information and objective evidence for all three parts. Look for:
- statements of action that are clear and concise
- descriptions that refer to specific documents and procedures
- the past tense ("was retrained", "has been revised") — a sign the work is done
- completion dates in the past, not promises of future action
- evidence that the action was carried out as described
- a check that the action hasn't created new problems elsewhere
Not every nonconformity needs all three parts. Where the lapse was genuinely accidental, the system is working well and recurrence is very unlikely, a correction alone may be enough. Where correction is impossible (a record that can't be recreated, for example), corrective action may still be justified.
4 A worked example (fictional)
| Part | Example response |
|---|---|
| Finding | A torque wrench in use carried a calibration label three months out of date |
| Correction | The wrench was withdrawn, calibrated and found within tolerance; work done with it since the due date was reviewed |
| Cause analysis | Calibration due dates were held on one spreadsheet checked by one person, who had been on long-term leave; no cover was arranged |
| Corrective action | Due-date reminders were added to the maintenance system, a second person was assigned, and all tools on the register were checked |
| What the auditor checks | The updated register, a sample of other tools, and whether the reminders have actually fired since |
5 Closing it
Some nonconformities can be closed from documents sent in; others need a look on site, which may mean another visit. Before closing, the APG says the auditor should review the containment, correction, cause analysis and corrective action results, and see objective evidence that the action has been fully implemented and is effective in preventing recurrence. Only then should the nonconformity be closed.